Illinois laws and regulations topic guide
Illinois Radon Resistant Construction Act
A labeled pipe in a new home tells you something about the construction, not the radon concentration in the air. For exam questions, keep three tasks separate: building the passive system, measuring radon and activating the system when needed. Each has a different purpose and different requirements.
Last reviewed:
The short answer
Illinois requires passive radon-resistant construction in the original construction of a single-family home or a dwelling containing two or fewer apartments, condominiums or townhouses. The requirement applies statewide and does not wait for a high test result. Builders, their subcontractors or radon contractors may install the passive features during construction. Section 25 reserves a radon vent fan or passive-to-active upgrade to a radon contractor with the appropriate mitigation authority. Passive construction is not a test result. Illinois and EPA recommend action at 4.0 pCi/L or more, including exactly 4.0.
Reviewed October 25, 2026. PSI Illinois III.K names the Radon Resistant Construction Act. The whole Additional Illinois Laws and Regulations domain has 10 of 40 scored state questions, with no page-specific quota. This lesson uses 420 ILCS 52 and the identified Part 422 provisions. The construction requirement began June 1, 2013. The current program is IEMA-OHS; older statute and rule text may use IEMA. This is a broker exam guide, not an installation specification or a project compliance inspection.
Separate the project, the system and the result
- Check the project definition. Original construction of the specified single-family or two-unit dwelling is covered. A 40-unit apartment building is not automatically within this Act's two-or-fewer definition, but that does not exempt it from every other requirement.
- Apply the statewide passive requirement. The buyer's county, a neighbor's result or a missing preconstruction test does not remove the duty for a covered new build. Then check the applicable local code; Section 35 permits standards at least as stringent as the agency rules.
- Trace the system's functions. Soil-gas collection, an appropriate membrane, sealed entry routes and a vent path work together. Slab and earthen crawlspace foundations need different collection details. An isolated pipe or sealing cracks alone does not establish a compliant system.
- Distinguish preparation from activation. Labels, accessible piping, the electrical provision and space for a future fan make later activation possible. They do not mean a fan is operating or that the home has been tested.
- Match the person to the work. A builder's passive-construction permission is not a mitigation license. Verify the appropriate radon service authority for measurement or activation; do not assume a broker, inspector, electrician or measurement-only credential supplies every permission.
- Read the measurement and the separate transaction duties. A valid result of 4.0 pCi/L meets the action level; a lower result is not a zero-risk warranty. Construction compliance, radon disclosure, contractual testing or repair duties and post-mitigation verification each need their own analysis.
| Issue | Rule or function | Do not assume |
|---|---|---|
| Covered project | Original single-family or qualifying two-or-fewer-unit dwelling | Every residential building has the same statutory scope |
| Statewide requirement | Passive construction in every Illinois area for covered new builds | Only high-radon counties are covered |
| Passive system | Natural convective flow; no vent fan | A labeled pipe means active mitigation |
| Subfloor preparation | Listed aggregate, sand-plus-matting or demonstrated alternative | Sand alone automatically satisfies the specified option |
| Slab soil-gas retarder | At least 6-mil polyethylene, 3-mil cross-laminate or equivalent; 12-inch laps | A thin sheet of any type is equivalent |
| Earthen crawlspace | Specified membrane and sub-membrane collection path | A basement pipe automatically serves it |
| Vent path | Roof discharge, required clearances, labels and drainage | It may simply end inside the attic |
| Future fan provision | Accessible location, electrical provision and specified pipe space | Fan readiness proves activation |
| Builder permission | Passive features during the new build | It also authorizes unlicensed fan installation |
| Action level | 4.0 pCi/L or more | Exactly 4.0 is below the threshold |
| Verification | A valid measurement of indoor air | A visual inspection or fan indicator is a radon test |
| Local rules | State rules or standards at least as stringent under Section 35 | A weaker local shortcut removes the statewide duty |
The distinctions that matter
| Distinction | How it works | What to notice |
|---|---|---|
| Original construction vs. existing-home renovation | The Act defines new residential construction as original construction of specified homes. A remodel or ordinary addition to an existing home is not automatically that defined project. | New dwelling or work on an existing one? |
| Passive system vs. active system | A passive system relies on natural airflow and has no vent fan. An active system uses a fan for mechanically driven soil depressurization. | Natural convection or powered suction? |
| Radon-resistant vs. radon-free | Construction resists entry and prepares for possible activation. It does not establish a zero reading or a substitute for testing. Even a measured level below 4.0 pCi/L is not a statement that exposure carries no risk. | Risk-reduction design or measured result? |
| Soil-gas retarder vs. vent pipe | The membrane reduces entry and bridges cracks. The vent path collects and routes soil gas to discharge above the roof. | Barrier or depressurization path? |
| Sub-slab vs. sub-membrane | Sub-slab collection serves concrete floors and permeable material beneath them. Sub-membrane collection serves earth floors or crawlspaces under sealed sheeting. | Concrete slab or exposed soil? |
| Builder work vs. licensed radon work | The builder or subcontractor exemption covers passive construction in the new build. Section 25 reserves fan installation and passive-to-active upgrades to a radon contractor with appropriate mitigation authority. A different license or job title alone does not supply that authority. | Passive rough-in or powered mitigation? |
| Construction inspection vs. radon test | An inspection can confirm visible components and code details. A radon measurement determines the indoor concentration. | Is it built correctly or what is the pCi/L? |
| 4.0 pCi/L guidance vs. legal construction trigger | The construction duty follows the project definition. The health action level concerns a measured result of 4.0 pCi/L or more. A covered new home does not need to test high before passive construction is required. | Health action level or mandatory build scope? |
| State minimum vs. local standard | The state rule establishes a statewide floor. A local government may administer and enforce equal or more stringent radon-resistant standards. | Baseline or added local protection? |
| Construction Act vs. Awareness Act | The Construction Act concerns defined new-build features. The Awareness Act separately addresses radon information and disclosures in covered sales and specified rental situations. Compliance with one does not by itself satisfy the other. | How built or what disclosed? |
| Fan indicator vs. radon measurement | An indicator can help show system operation or a failure condition. It does not measure the radon concentration in the occupied air or replace a post-mitigation test. | Equipment status or air result? |
Work through the facts
A new duplex
A builder begins original construction of a duplex in an Illinois county that the buyer believes has low radon potential. The builder argues that no passive pipe is necessary because no elevated test exists.
- A duplex is a dwelling containing two apartments.
- The project is original construction in Illinois.
- The statewide mandate is not limited to selected radon zones.
- The construction duty does not depend on a preconstruction indoor-air result.
- Passive radon-resistant construction must be included.
Answer: The new duplex is covered statewide and requires the passive construction package.
A large new apartment building
A developer constructs a new 40-unit apartment building and asks whether the definition in 420 ILCS 52 automatically controls the project.
- The project is original residential construction.
- However, the statutory definition names a single-family home or dwelling containing two or fewer apartments, condominiums, or townhouses.
- Forty apartments exceed that stated scope.
- The Act's specific definition therefore does not automatically cover the project.
- Other state codes, local ordinances, financing rules, or voluntary standards still require review.
Answer: The 40-unit building is outside this Act's stated new-residential-construction definition, but other requirements may apply.
The pipe has no fan
A buyer sees a labeled pipe running from beneath the slab through the attic and above the roof. There is an outlet and open pipe space in the attic but no fan.
- The below-slab-to-roof path is consistent with passive construction.
- The outlet and attic space prepare for future activation.
- The absence of a fan means it is not an active soil-depressurization system.
- Natural airflow can occur without powered suction.
- A valid radon test is still needed to know the indoor concentration.
Answer: The facts describe a passive, fan-ready radon system, not proof of active mitigation or a low reading.
The builder wants to add the fan
After a new home tests at 6.2 pCi/L, the general contractor offers to install a vent fan personally because the passive pipe is already present. The contractor has no radon mitigation license. The contractor is working for the buyer, not on a dwelling in which the contractor resides.
- The test result raises a mitigation concern under current health guidance.
- The passive pipe makes conversion easier but does not expand the builder's legal scope.
- Section 25 reserves the stated fan installation and passive-to-active upgrade to a radon contractor with appropriate mitigation authority.
- The general contractor is not stated to hold that license.
- A licensed radon contractor should design and perform the activation.
Answer: The unlicensed general contractor may not perform the fan upgrade; use a licensed radon contractor.
Two separated foundation areas
A covered home has a basement and a crawlspace separated so soil gas cannot move freely between their collection areas. The plan uses one pipe only beneath the basement slab and no crawlspace membrane path.
- The basement calls for a sub-slab collection path.
- The earth-floor crawlspace calls for a sealed sub-membrane path.
- Separated foundation areas cannot be assumed to communicate.
- The combination-foundation rule calls for separate radon vent pipes in the foundation areas or a continuous drain-tile connection, with the specified common outlet.
- The current one-pipe basement-only plan leaves the crawlspace unserved.
Answer: Have the qualified designer or installer address both foundation types under the applicable rule. A basement-only pipe does not establish that the separate crawlspace is served.
The inspection passed but no one tested
A local official confirms the passive components in a new home satisfy the adopted construction code. The seller then advertises the home as tested radon safe, although no indoor-air measurement occurred.
- The official confirmed construction compliance, not an air concentration.
- Passive features resist entry and prepare for mitigation.
- Radon cannot be detected by the senses.
- Only a measurement produces a pCi/L result.
- The advertised claim is unsupported by the inspection alone.
Answer: Do not claim the home was tested or is radon safe. State the verified passive features and obtain a valid measurement for concentration claims.
Exactly 4.0 counts
A valid radon report for a new home is 4.0 pCi/L. The seller says no reduction is recommended because the result must be greater than 4.0.
- The action wording is 4.0 pCi/L or more.
- Exactly 4.0 meets that threshold.
- The result supports the reduction recommendation; it does not by itself decide who must pay under a contract.
Answer: The seller's threshold statement is wrong. Address the result with an appropriately licensed radon professional and the actual transaction terms.
The buyer wants a guarantee from the pipe
A seller supplies the passive-system installation record but has no radon test. The buyer asks the broker to promise that the air measures below the action level.
- Installation evidence and air measurement are different evidence.
- A construction record does not supply a pCi/L result.
- The broker should describe the verified feature without inventing a test or a guarantee.
Answer: Explain what the record shows and arrange appropriate measurement under the transaction terms. Do not promise a result from the pipe alone.
The wrong credential for the fan
A person holds only a radon measurement credential and offers to activate a client's new-construction system, relying on the statutory label radon contractor.
- The construction Act's definition refers to licensed measurement or mitigation work.
- Part 422 separately recognizes measurement and mitigation categories.
- The actual work requires the appropriate mitigation authority; a broad label does not expand a measurement-only credential.
Answer: Verify the appropriate mitigation qualification before assigning the activation. Measurement authority alone is not enough.
A resident tests the home
A person uses a radon kit in the dwelling where the person resides. Another student says every unlicensed resident measurement is forbidden.
- Section 422.30(a) provides a resident exemption from the Part's licensing requirements.
- That is different from offering testing services for someone else's property.
- A licensing exemption also does not establish that a test followed the appropriate protocol.
Answer: The absolute licensing claim is incorrect. Apply the resident exemption and the actual measurement requirements.
Passive work and a separate sales disclosure
A covered new home has passive features. In an otherwise covered sale, the seller wants to omit the radon information and disclosure because the construction requirement was met.
- The construction duty and the sales-disclosure duty arise under different provisions.
- Passive features are not a test result or an automatic Section 20 sales-disclosure exclusion.
- Section 10 governs the applicable sales information and disclosure timing.
Answer: Complete the applicable disclosure duties separately. Construction compliance alone is not an exemption from them.
Sand is not the whole listed option
A covered slab plan uses four inches of sand but omits the geotextile drainage matting. It claims compliance only with the listed sand option, with no demonstrated alternative design.
- The sand option in Section 422.160(b)(2) includes the specified matting.
- A four-inch depth does not erase the rest of that option.
- A separate demonstrated-capability alternative cannot simply be assumed.
Answer: The stated sand-only facts do not establish the listed option. Have the qualified project professional verify and correct the design.
Mistakes to avoid
- Radon-resistant construction is required only in high-radon counties. The statute and rule apply to defined new residential construction in all areas of Illinois.
- Every new apartment building is within the Act. The definition is limited to a single-family home or a dwelling containing two or fewer apartments, condominiums, or townhouses.
- A passive system always includes an operating fan. Passive construction relies on natural airflow. Adding a fan converts or upgrades it to active mitigation.
- A passive pipe proves the home is below 4.0 pCi/L. Construction does not generate an indoor-air result. The home must be tested to determine its radon concentration.
- Sealing cracks alone is the required system. Sealing is one entry-control component. The compliant passive package also needs a collection layer or membrane and vent path.
- The radon pipe may end inside the attic. The vent path terminates above the highest roof under the rule's stated height and opening-distance requirements.
- Any builder can add the fan after a high test. The passive builder permission does not authorize the stated client-service fan upgrade. Section 25 reserves that work to a radon contractor with appropriate mitigation authority.
- A home inspector can certify a radon concentration by viewing the system. A visual inspection assesses components. A valid radon measurement is needed for concentration.
- A local government may replace the state rule with a weaker code. Local radon-resistant construction regulations must be at least as stringent as the state rules.
- The construction Act is the seller's radon disclosure law. New-build construction and transaction disclosure serve different purposes under different statutes.
- Only a result greater than 4.0 pCi/L meets the action level. The recommendation includes 4.0 pCi/L or more. Exactly 4.0 counts.
- Every resident needs a radon license to test the dwelling where the resident lives. Section 422.30(a) supplies a resident licensing exemption. That does not establish authority to provide radon services to clients.
- An outlet, fan or pressure indicator proves a low indoor result. Those concern the equipment. Use an appropriate radon measurement to assess the air concentration.
Check your understanding
These are original teaching questions, not recalled or predicted PSI questions. Answer first, then explain why the other choices fail.
1. Which project is new residential construction under 420 ILCS 52?
- An ordinary remodel of an existing duplex
- An ordinary addition that does not create a new dwelling
- Original construction of an Illinois duplex
- Original construction of one 40-apartment dwelling
Show answer and explanation
Answer: C. Original construction of an Illinois duplex
A duplex is original construction of a dwelling containing two apartments, within the statutory definition.
2. What powers a passive radon-resistant system?
- A sump pump motor
- A mandatory vent fan
- A furnace blower
- Natural convective airflow
Show answer and explanation
Answer: D. Natural convective airflow
Passive new-construction pipe relies on natural airflow. Mechanically driven suction is active mitigation.
3. Who may install passive radon-resistant construction during a covered new build?
- Only a radon measurement professional, with no builder permission
- The residential builder, subcontractors, or a radon contractor
- Only the county building inspector personally
- Only a radon mitigation professional, with no builder permission
Show answer and explanation
Answer: B. The residential builder, subcontractors, or a radon contractor
Section 25 permits those parties to install the passive construction package during new residential construction.
4. Who has the required authority for a client's new-construction passive-to-active radon fan upgrade under the stated rule?
- Any unlicensed electrician
- The listing broker
- A radon contractor with appropriate mitigation authority
- Any home inspector
Show answer and explanation
Answer: C. A radon contractor with appropriate mitigation authority
Section 25 reserves the fan or upgrade to a radon contractor; the applicable mitigation qualification matters. A broker, inspector or measurement-only credential is not itself that authority.
5. What does code-compliant passive construction prove about indoor radon concentration?
- Nothing specific until the home is tested
- A measured result that remains valid after every building alteration
- A substitute for all later indoor-air measurements
- A guarantee that the concentration is below 4.0 pCi/L
Show answer and explanation
Answer: A. Nothing specific until the home is tested
Passive features resist entry and prepare for mitigation, but only an indoor-air measurement determines the concentration.
6. A valid new-home test result is exactly 4.0 pCi/L. Which statement matches Illinois and EPA action guidance?
- The number is a guarantee of no health risk
- Reduction is recommended only above 4.0
- The result meets the 4.0-or-more action level
- The passive pipe cancels the result
Show answer and explanation
Answer: C. The result meets the 4.0-or-more action level
Exactly 4.0 meets 4.0 or more. The recommendation does not by itself determine the parties' contract obligations or who pays.
7. A covered new duplex is in a county thought to have low radon potential. No elevated indoor test exists. Which is correct?
- The statewide passive requirement still applies
- Passive construction may always be omitted
- A neighbor's low result exempts the project
- Only the buyer's preference controls the statutory duty
Show answer and explanation
Answer: A. The statewide passive requirement still applies
Section 20 and Rule 422.160(a) apply statewide to the defined new construction. A high preconstruction result is not the trigger.
8. A person tests the dwelling where that person resides. Which statement is supported by Rule 422.30(a)?
- The resident exemption applies only if the test result is below 4.0 pCi/L
- A resident licensing exemption exists, but it does not establish protocol compliance or client-service authority
- Every resident needs a measurement license for the dwelling where the resident lives
- The resident exemption authorizes paid testing in other people's homes
Show answer and explanation
Answer: B. A resident licensing exemption exists, but it does not establish protocol compliance or client-service authority
The rule exempts the stated resident from its licensing requirements. It is not a substitute for proper measurement or a license to provide client services.
9. A covered slab design relies only on the listed four-inch sand option but omits its drainage matting. No demonstrated alternative is established. Which follows?
- Sand alone does not establish the specified sand-plus-matting option
- The radon disclosure form replaces the layer
- The builder license waives the matting
- Depth alone satisfies every part of that option
Show answer and explanation
Answer: A. Sand alone does not establish the specified sand-plus-matting option
Rule 422.160(b)(2) includes geotextile drainage matting. A separate demonstrated-capability alternative must actually be established, not assumed.
10. A seller in an otherwise covered sale supplies passive-system paperwork and wants to skip the applicable radon disclosure. Which is correct?
- Apply the separate disclosure duties; construction alone does not eliminate them
- Disclosure may always wait until closing because the passive features exist
- A construction record automatically replaces all prior elevated test records
- Passive construction automatically creates a disclosure exclusion
Show answer and explanation
Answer: A. Apply the separate disclosure duties; construction alone does not eliminate them
Construction and Awareness Act duties serve different purposes. Apply the actual sale and its disclosure rules and exclusions separately.
11. A system indicator appears normal after fan activation. No post-mitigation air test is available. What is the sound conclusion?
- The air concentration is exactly zero
- Every below-grade room must have the same result
- Equipment status does not establish the indoor radon concentration
- A pressure indicator is the same as a radon detector
Show answer and explanation
Answer: C. Equipment status does not establish the indoor radon concentration
Use appropriate measurement to evaluate concentration and effectiveness. A fan or function indicator alone does not supply the air result.
12. A developer asks only whether a new 40-apartment building falls within the definition in 420 ILCS 52/15. Which is correct?
- It is outside this Act's stated dwelling definition, while other applicable requirements still need review
- Only the buyer's preferred label determines coverage
- It is automatically within the two-or-fewer-unit definition
- It is exempt from every radon or building requirement
Show answer and explanation
Answer: A. It is outside this Act's stated dwelling definition, while other applicable requirements still need review
The specific construction definition names a single-family home or dwelling containing two or fewer of the listed units. Do not turn a scope exclusion into a blanket exemption from all other law.
Common questions
What does the Illinois Radon Resistant Construction Act require?
Section 20 requires passive radon-resistant construction in all new residential construction within the Act's definition. The original construction of a single-family home or dwelling containing two or fewer apartments, condominiums or townhouses is the key scope. The mandate is statewide and does not depend on a high preconstruction test result.
When did the Illinois construction requirement begin?
The operative construction requirement took effect June 1, 2013. It is not a newly created 2026 requirement. For a particular project, examine the actual construction and applicable code facts with the responsible building official rather than treating a home's advertised year alone as a compliance certificate.
Does the Act automatically cover every new apartment building or renovation?
No. Apply the original-construction and specified dwelling definition. A 40-apartment building is outside that particular two-or-fewer scope, and an ordinary existing-home remodel is not automatically original construction of a new dwelling. Other state or local requirements, transaction duties and health recommendations can still apply.
Is passive radon construction the same as an active mitigation system?
No. Passive pipe relies on natural convective airflow; active soil depressurization uses a mechanically driven system. A future fan location, outlet and labeled pipe can be passive preparation. Adding the fan or making the passive pipe active is a separate step with its own requirements.
What components make up the passive construction package?
For ground-contact floors, the rule addresses the appropriate gas-permeable layer and soil-gas retarder, sealed entry routes, and sub-slab or sub-membrane collection and venting. It also covers drainage, roof termination, identification and future activation provisions. Foundation type matters. A membrane, sealed crack or isolated pipe by itself does not establish that the whole package complies.
What are the main slab-layer and membrane details to remember?
The listed subfloor options include at least four inches of the specified clean aggregate, or at least four inches of sand with the specified geotextile drainage matting, or a demonstrated-capability alternative. The slab retarder provision permits at least 6-mil polyethylene, 3-mil cross-laminate or equivalent flexible sheeting, with at least 12-inch laps and attention to penetrations and damage. The crawlspace subsection has its own membrane requirements. Use the full rule for installation, not these exam notes.
Does a crawlspace use the same collection arrangement as a concrete slab?
Not necessarily. The rule separately addresses sub-membrane collection under a sealed soil-gas retarder and sub-slab collection under a concrete floor. Combination foundations need the specified separate collection paths or continuous drain-tile connection. Do not assume a basement-only pipe reaches an isolated crawlspace.
Can the vent pipe end inside the attic?
No. The passive vent must discharge above the roof with the rule's required height and opening clearances. It also needs drainage, identification and the applicable installation details. The attic is a possible accessible future fan location, not an indoor exhaust destination.
What prepares the system for a future fan?
The rule addresses access outside and above habitable space, with a specified rooftop-electrical alternative, an electrical circuit ending at a single outlet in an accessible approved box at the anticipated attic fan location, and at least three feet of attic pipe height for the anticipated active SSD fan. These provisions are preparation, not evidence that a fan is installed or working.
Who may install passive construction, and who may activate it?
During the covered new build, the builder, subcontractors or a radon contractor may install the passive work. Section 25 reserves a radon vent fan and passive-to-active upgrade to a radon contractor. Verify the appropriate mitigation authority for that work. A general contractor, electrical, home-inspection, real estate or measurement-only credential does not by itself supply it.
Are there any exceptions to radon licensing requirements?
Yes. Section 422.30(a) includes measurements or mitigation in a dwelling where the person resides, and subsection(g) separately exempts the builder or subcontractor installing passive construction. These are conditional licensing exceptions. They do not authorize a broker or hired builder to provide every radon service to clients. For a new-construction fan or passive-to-active upgrade, apply Section 25 and the specific mitigation requirements. This lesson does not infer blanket do-it-yourself activation permission from the resident exemption.
Does exactly 4.0 pCi/L meet the radon action level?
Yes. Illinois and EPA recommend reducing radon at 4.0 pCi/L or more. Exactly 4.0 meets that wording. A result below 4.0 is not a zero-risk guarantee. Follow the appropriate measurement and professional follow-up for the situation; this lesson does not diagnose an individual's health risk.
Does a passive system or a successful building inspection replace testing?
No. An installation record or inspection addresses construction, while a radon measurement supplies an indoor-air result. EPA recommends testing a new home after occupancy even when it has radon-resistant features. In a purchase, follow the applicable Illinois transaction protocol and contract terms rather than assuming a general home test settles every transaction issue.
Does a running fan or system indicator prove the air is below 4.0?
No. Equipment status and indoor concentration are different. Test to evaluate the result after mitigation and follow the applicable protocol and professional instructions. Do not advertise a concentration or a tested-safe guarantee solely because a fan or indicator appears to work.
Can a local code remove the statewide construction duty?
Section 35 permits adoption of the agency rules by reference or regulations at least as stringent as those rules. Section 30 permits local administration and enforcement of adopted radon construction provisions. Check the actual local code and responsible official; a claimed weaker shortcut does not remove the duty for a covered project.
Is this the same law as Illinois radon disclosure?
No. The Construction Act concerns defined new builds. The Awareness Act separately covers radon information and disclosures in covered sales and specified rental situations. For sales, Section 10 states that it does not itself imply a seller duty to test or mitigate; that is not a blanket release from construction, contract, other-law or disclosure duties. A passive system does not automatically create a sales-disclosure exclusion.
What can an Illinois broker accurately say about a passive system?
Describe the supported facts, such as an available installation record or the presence of labeled passive components, without claiming a professional compliance inspection or an unmeasured concentration. Obtain the appropriate test or specialist review for the question actually being asked. A broker license does not independently authorize radon measurement or mitigation services.
Are these official PSI questions or a construction compliance checklist?
No. They are original practice scenarios supporting the public Illinois III.K topic. The rule details explain the distinctions, not a complete design or inspection procedure. A practice score is not a validated passing prediction, and the page does not approve an actual installation or decide a disputed contract obligation.
Keep practising
Your next practice step
Put environmental disclosure into practice
Distinguish the property, person and condition covered by each disclosure rule.
These web resources are free. The app has a separate free starter tier and optional paid full access.
Official sources and scope
Checked October 25, 2026 against the identified Illinois Act and rule passages, current IEMA-OHS publications and EPA guidance updated September 16, 2026. The review distinguishes current indexed rule text from an older local-government reprint used for corroboration. All practice scenarios are original. These notes do not approve a design, test protocol, licensing exception, health assessment or actual contract obligation.
- PSI June 24, 2026: Illinois III.K construction topic
- 420 ILCS 52: construction scope, installers and local standards
- 32 Ill. Adm. Code 422.160: passive new-construction methods
- 32 Ill. Adm. Code Part 422: licensing, measurement and mitigation distinctions
- IEMA-OHS Radon Publications: action level and separate protocols
- EPA: radon-resistant new homes still need testing
- IEMA radon system checklist: equipment inspection and air measurement
- 420 ILCS 46/10: separate sales information and disclosure duties
This is exam preparation, not advice for a specific transaction. State law and the applicable facts control. Our editorial and corrections process explains how to report an issue.